Coordinated 7FA Hot Gas Path and 7FH2 Generator Inspection and Repair

Posted to MD&A

image credit: MD&A

Connect with MD&A

Fill out this form to receive more information from MD&A.

Mechanical Dynamics & Analysis (MD&A) completed a carefully coordinated 7FA gas turbine hot gas path inspection, 7FH2 generator inspection and repairs in just 19 days, providing all services, labor, and parts.

The customer contracted MD&A to perform the inspection and emergent repairs on a tight schedule. Our industry experts completed the work on time maintaining full customer communication throughout the outage utilizing our on-site project management.

For the gas turbine, all combustion and hot gas path components were removed, cleaned, and inspected. All required hardware was provided by MD&A. Our San Antonio Service Center, which is our Gas Turbine Parts Service Facility, refurbished all combustion parts of fuel nozzles, combustion system liners, liner caps, transition pieces and flow sleeves.

The stage 1 nozzle was replaced with a new assembly. The site team replaced both the right and left stage 1 forward wheelspace thermocouple guide tube assemblies. The stage 2 and stage 3 nozzle segments were also replaced. New shroud blocks and new installation hardware were provided for all stages. Moderate fretting was observed that warranted replacement of the exhaust frame flex seals.

Simultaneously, MD&A experts removed both turbine-end and collector-end upper half end shields to perform a generator minor inspection consisting of stator and field visual inspections, including in-situ robotic inspections, ELCID and electrical testing.

The Generator Specialist immediately recognized that the stator had significant connection ring damage that could have led to catastrophic damage had it continued to operate.

 

The solution: MD&A expeditiously removed, reverse engineered, and replaced the damaged components with no impact to overall outage schedule (5 days total repair time).

Scoring was identified on both the turbine-end and collector-end journals. The lower half bearings had moderate abrasion/scoring. Minor babbit damage was also noted. The turbine-end and collector-end hydrogen gas and air side seals were found in poor condition and replaced.

Winders were mobilized to perform numerous tie repairs on each end of the unit and connection ring replacement on the collector end with the rotor still in place.

As a result of MD&A’s impact testing and modal analysis, additional blocking and ties were made on the connection rings to ensure the unit will not see this type of problem again.

Post-project, MD&A specialists completed DLN tuning of the gas turbine.

At project conclusion, comprehensive reports were provided listing each step of the process and its engineering rationale, along with detailed analysis and long-term predictions and recommendations.

MD&A site and shop repair teams worked closely together to deliver first class service. MD&A’s provides a one-stop shop solution for turbine & generator services, parts, and repairs. Call MD&A today at +1 (518) 399-3616

Also be sure to sign up for our MD&A Insight e-newsletter delivered quarterly. Get our turbine-generator expert’s case studies and tips! Fill in sign up form and SUBSCRIBE! 

Jay Eldridge's picture

Thank Jay for the Post!

Energy Central contributors share their experience and insights for the benefit of other Members (like you). Please show them your appreciation by leaving a comment, 'liking' this post, or following this Member.

MD&A
Mechanical Dynamics & Analysis (MD&A) provides power generators around the globe with a full-service, OEM-alternative for services, parts, and repairs for Gas Turbines, Steam Turbines and Generators.

Discussions

Matt Chester's picture
Matt Chester on May 12, 2020 9:45 pm GMT

The Generator Specialist immediately recognized that the stator had significant connection ring damage that could have led to catastrophic damage had it continued to operate.

Can you share how common of an issue this might be, and what sort of timeframe it might be expected to develop over? 

Thanks for sharing!

Jay Eldridge's picture
Jay Eldridge on May 13, 2020 7:01 pm GMT

These types of issues have become more common in the industry over the past 20 years due to manufacturers changing materials and process.  Dusting and greasing of connection ring ties is a very common issue that has always plagued large generators however this issue became more significant when the weight of the dislodged block and the remaining tie material acted like a saw cutting through the ground wall insulation and copper.  This unit was only a few years old.  These repairs were made with the field in place.  We have seen generators with only 2-3 services fail due to issues such as this.  It’s very important for new units to receive periodic inspections by a qualified individual.  Just because it’s a new unit doesn’t mean that it won’t have issues that need to be addressed soon after initial start-up.  Thanks!

Get Published - Build a Following

The Energy Central Power Industry Network is based on one core idea - power industry professionals helping each other and advancing the industry by sharing and learning from each other.

If you have an experience or insight to share or have learned something from a conference or seminar, your peers and colleagues on Energy Central want to hear about it. It's also easy to share a link to an article you've liked or an industry resource that you think would be helpful.

                 Learn more about posting on Energy Central »