In partnership with AESP: The increasing roles of DERs, connected technology and Big Data are driving rapid change in energy efficiency. As we shape the Utility of the future, this community will help you keep up with the latest developments. 

Meisam Moghadasi's picture
Postdoctoral Research Fellow Materials and Energy Research Center (MERC)

▪ Currently acting as a postdoctoral research fellow in the field of solar energy, artificial intelligence and machine learning. ▪ Summary — Engineering Manager with 10+ years of hands-on...

  • Member since 2021
  • 3 items added with 903 views
  • Nov 27, 2022
  • 243 views

This study develops reliable and robust machine learning (ML) models to predict the outlet air temperature and humidity and thermal efficiency of a solar air heater (SAH). Also, the application of predictive models for optimal control of the SAH operation is proposed. For this, the work contains three main parts: (a) a vertically-mounted symmetrical SAH was installed outside of a building room and operated throughout the winter of 2022. (b) By conducting experiments for five air mass flow rates, a large dataset with more than 62,500 sample points was collected. (c) Six input features containing time, environmental-related attributes, and SAH variables were applied to develop several state-of-the-art ML algorithms. To figure out the most accurate models for predicting output variables, the dataset was partitioned into three parts. Also, various modeling performance evaluation criteria were calculated and compared on the validation and test sets. Among these models, the gradient boosting machine algorithm based on LightGBM implementation achieved the best degree of generalization in modeling the target variables. The results demonstrated that the developed models obtained the lowest R-squared and the highest mean absolute percentage error of 0.9827 and 2.95%, respectively, on the test set. Moreover, the offline analysis of SAH operation based on the proposed control scheme demonstrated that 350 kWh of thermal energy can be generated during the application in the one-year winter season, 24% more than SAH operation without a model-based control strategy.

Discussions

No discussions yet. Start a discussion below.

Meisam Moghadasi's picture
Thank Meisam for the Post!
Energy Central contributors share their experience and insights for the benefit of other Members (like you). Please show them your appreciation by leaving a comment, 'liking' this post, or following this Member.
More posts from this member

Get Published - Build a Following

The Energy Central Power Industry Network is based on one core idea - power industry professionals helping each other and advancing the industry by sharing and learning from each other.

If you have an experience or insight to share or have learned something from a conference or seminar, your peers and colleagues on Energy Central want to hear about it. It's also easy to share a link to an article you've liked or an industry resource that you think would be helpful.

                 Learn more about posting on Energy Central »